EZMakaan offers FLUKE 376 FC True-Rms AC/DC Clamp Meter With IFlex at the best price in Pakistan.
POWER |
AC Voltage |
Range 374 and 375 600.0 V 376 1000 VAccuracy 1.5% ± 5 digits (20 – 500 Hz)Resolution 374 and 375 0.1 V 376 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
DC Voltage |
Range 374 and 375 600.0 V 376 1000 VResolution 374 and 375 0.1 V 376 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V)Accuracy 1% ± 5 digits |
SUMMARY |
Crest factor |
(50/60 Hz) 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 |
Crest Factor (AC Current) |
(50/60Hz) 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
EMC Standard |
EN 61326-1:2006 |
mV dc |
Range 375 and 376 500.0 mVResolution 0.1 mVAccuracy 1% ± 5 digits |
Resolution (AC Current) |
374 and 375 0.1 A (≤ 600 A) 1 A (≤ 2500 A)376 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
Temperature Coefficients |
Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
Capacitance |
Range 1000 μFResolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF)Accuracy 1% ± 4 digits |
DC Current |
Range 374 and 375 600.0 A 376 999.9 AResolution 0.1 AAccuracy 2% ± 5 digits |
Resistance |
Range 374 6000 Ω375 and 376 60 kΩResolution 374 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω)375 and 376 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ)Accuracy 1% ± 5 digits |
Accuracy |
2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) |
Resolution |
374 and 375 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
Range |
374 and 375 376 600.0 A 999.9 A |
Size |
(L x W x H) 246 mm x 83 m x 43 mm |
HARDWARE FEATURES |
Weight |
388 g |
TECHNICAL SPECIFICATION |
Accuracy (AC Current) |
3% ±5 digits (5 – 500 Hz) |
Operating Altitude |
3000 meters |
Operating Humidity |
Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
Operating Temperature |
10°C – +50°C |
Range (AC Current) |
2500 A |
Safety Compliance |
CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
Storage Altitude |
12,000 meters |
Storage temperature |
-40°C – +60°C |
GENERAL SPECIFICATION |
Frequency via Flexible Current Probe |
Range 375 and 376 5.0 – 500.0 HzResolution 0.1 HzAccuracy 0.5% ± 5 digitsTrigger Level 5 – 20 Hz, ≥ 25 A 20 – 100 Hz, ≥ 20 A 100 – 500 Hz, ≥ 25 A |
Frequency via Jaw |
Range 375 and 376 5.0 – 500.0 HzResolution 0.1 HzAccuracy 0.5% ± 5 digitsTrigger Level 5 – 10 Hz, ≥10 A 10 – 100 Hz, ≥5 A 100 – 500 Hz, ≥10 A |
BATTERIES & RUNTIME |
Battery type |
2 AA, NEDA 15A, IEC LR6 |
Reviews
There are no reviews yet.